VueLife® "C" Series Bags

VueLife® “C” Series Bags are designed for the culturing of suspension cells, such as lymphocytes and monocytes.  All VueLife bags are made from the highest quality USP Class VI fluorinated ethylene propylene (FEP) material and provides permeability to oxygen and carbon dioxide whilst remaining impermeable to water for improved culture and expansion. 

VueLife-C-Series-bag-drawings-and-measurements

VueLife® "C" Series Specifications

Product  Recommended Process Volume *Approx. Maximum Fill Volume  Approx. Interior Surface Area
(2 x Bag Face)
Standard Ports & Tubing Qty/Case 
32-C 32 mL 40 mL 87 cm2 1 FLV port; 7” length of PVC tubing that goes to “Y” with 2 more lengths of 7” tubing, one length sealed off, and one length with female luer port at end 10
72-C 72 mL 175mL 193 cm2 1 FLV port; 7” length of PVC tubing that goes to “Y” with 2 more lengths of 7” tubing, one length sealed off, and one length with female luer port at end 10
118-C 118 mL 275 mL 277 cm2 1 FLV port; 7” length of PVC tubing that goes to “Y” with 2 more lengths of 7” tubing, one length sealed off, and one length with female luer port at end 10
119-C 119 mL 285 mL 286 cm2 1 FLV port; 7” length of PVC tubing that goes to “Y” with 2 more lengths of 7” tubing, one length sealed off, and one length with female luer port at end 10
197-C 198 mL 500 mL 502 cm2 1 FLV port; 7” length of PVC tubing that goes to “Y” with 2 more lengths of 7” tubing, one length sealed off, and one length with female luer port at end 10
290-C1 290 mL 900 mL 658 cm2 1 FLV port; 7” length of PVC tubing that goes to “Y” with 2 more lengths of 7” tubing, one length sealed off, and one length with female luer port at end 10
750-C1 750 mL 2,500 mL 1,643 cm2

1 FLV port; 1 spike port; 1 length of PVC tubing that goes to “Y” with 2 more lengths of tubing, one length sealed off, and one length with female luer port at end

10

*The maximum fill volume is a calculated value for the theoretical maximum volume based on the bag dimensions. There is no data supporting usage at this volume. The recommend process volume for cell culture is provided to achieve the optimal 1 cm height when the bag is lying flat. Using a volume above the recommended process volume has not been studied.

Product Documents

Download Selected (0)
Vuelife®" C" Series

Learn about VueLife® "C" Series cell culture bag applications, features & benefits, standard ports & tubing options, and bag size specifications.

PDF | 2 pages | 619.5 KB
Vuelife®" C" Series
T-Cell Culture in Vuelife® "C" Series Bags

T Cell Culture Results in VueLife® “C” Series Bags

PDF | 3 pages | 464.5 KB
T-Cell Culture in Vuelife® "C" Series Bags
Vuelife® "C" Series Bags General Use Guidelines

General Use Guidelines for VueLife® "C" Series Bags

PDF | 4 pages | 644.9 KB
Vuelife® "C" Series Bags General Use Guidelines
Cell Therapy Solutions

Learn about our cell therapy product lines, custom solution offerings, and manufacturing capabilities.

PDF | 13 pages | 7.56 MB
Cell Therapy Solutions
Fluid Transfer Assembly for Cell Therapy
Fluid Transfer Assemblies

All fluid transfer assemblies are manufactured to exceed expectations for quality and performance.

Lab room with flow hood
Saint-Gobain Life Sciences Lab

This laboratory tests products for the Cell and Gene Therapy market.